Parameters and specifications
max. supply voltage | 28 V DC |
max. load current | 50 A |
built-in additional resistors | 10 Ω, 20 Ω, 40 Ω, 120 Ω for emission measurement |
The switching behavior of the BS 200N series solid-state switches must be verified at a load of 0.6 to 50 uH.
TheCA of the BS 200N is directly connected to the output of the BS 200Nx. The switching parameters of the BS 200Nx are measured with the load connected.
In addition, the CA BS 200N includes resistors of 10 Ω, 20 Ω, 40 Ω and 120 Ω, which are required by the standards used for transient emission measurements according to ISO 7637-2:2011 and ISO 7637-2:2004.
Standards: ISO 7637-1:1990, ISO 7637-2:2004, ISO 7637-2:2011