Parameters and specifications
frequency range | 1 to 1000 MHz |
rated output power | 300 W guaranteed (40 W nominal) |
output power at 1 db compression | 25 W guaranteed (35 W nominal) |
amplification | 44 dB minimum |
harmonics at P1 dB | -20 dBc |
supply voltage | 90-264 VAC, single phase |
- new high power density design has made it possible to produce a 30 W 1 MHz to 1 GHz amplifier in a compact 4 U size, with a minimum linear power of 25 W, this amplifier is ideal for RF immunity testing in GTEM, these amplifiers can be easily integrated with Teseq immunity instruments such as the NSG 4070 or ITS 6006 and Teseq GTEM to create turnkey IEC 61000-4-3 test systems
- new color touch screen display provides instant visual indication of forward and reverse power along with the current operating status of the amplifier and access to diagnostic information such as gate current and heat sink temperature
- most commonly used for standards IEC/EN 61000-4-3, IEC/EN 61000-4-6, IEC/EN 61000-4-20, IEC/EN 61000-4-21, CISPR 24, EN 61000-6-1, EN 61000-6-2, IEC 60533, IEC 60601-1-2, IEC 61326, MIL STD 461, RTCA/DO 160, ISO 11452-3, ISO 11452-5, ISO 11452-11, SAE J1113-24, SAE J1113-27
Downloads and links
- Brožura Teseq CBA Series BROADBAND POWER AMPLIFIERS.pdf (5103.3kB)
- Tabulka Teseq CBA Series BROADBAND POWER AMPLIFIERS.pdf (843.2kB)
- Datasheet - CBA1G-030D.pdf (572.2kB)
- Further information on the manufacturer's website
Need some advice?
Call us on +420 325 610 123 and ask for a specialist in this field.