Parameters and specifications
frequency range | 0.15 to 230 MHz |
rated output power | 80 W guaranteed (90 W typical) |
output power at 1 db compression | 70 W guaranteed (80 W typical) |
amplification | 50 dB |
harmonics at P1 dB | better than -20 dBc |
supply voltage | 85-264 VAC, three phase |
- designed specifically for EMC testing, this Class A amplifier is ideally suited for Bulk Current Injection (BCI), injection clamp and CDN testing to IEC 61000-4-6 levels up to 10 V emf
- class A design ensures high reliability and linear performance with low distortion over the entire frequency range, this design also ensures that the amplifier will operate at full power, even when previously connected to empty or short-circuited
- the amplifier is powered from a high efficiency, high power factor switching power supply that allows operation over a wide voltage range, the unit is air-cooled with integrated fans and is protected against faulty cooling by sensing excessive temperature, there is a safety interlock connector that the user can short to the carcass to place the amplifier in standby mode, there are indicators on the front panel to indicate overheat function
- most commonly used for IEC/EN 61000-4-6, CISPR 24, EN 61000-6-1, EN 61000-6-2, IEC 60533, IEC 60601-1-2, IEC 61326, MIL STD 461, RTCA/DO 160, ISO 11452-3, ISO 11452-5, SAE J1113-24
Downloads and links
- Brožura Teseq CBA Series BROADBAND POWER AMPLIFIERS.pdf (5103.3kB)
- Tabulka Teseq CBA Series BROADBAND POWER AMPLIFIERS.pdf (843.2kB)
- Datasheet - CBA230M-080.pdf (567.9kB)
- Further information on the manufacturer's website
Need some advice?