Parameters and specifications
current range/channel |
max 300 A pulsed and 200 A continuous |
current accuracy |
0.03% of range |
voltage range (compliance) |
+300 mV to +10 V |
polarization voltage |
up to +10 V |
voltage accuracy |
control 0.02% of range |
EIS frequency range |
10 mHz to 10 kHz |
- four-wire connection to cells
- two auxiliary voltage measurement lines on each channel for DC and EIS anode/cathode characterization
- system software uses EIS modelling with real-time updates for trend analysis and cell diagnostics
- unique EIS EoH cell classification algorithm designed for NISSAN LEAF with the ability to be adapted for other assemblies
- new flux gate current sensor with excellent temperature stability
- "Direct to Disc" technology for direct data storage on the network drive without PC assistance increases reliability in the event of a power failure while reducing the load on the local network
- optional 16-channel PoE (Power over Ethernet) temperature/voltage measurement unit available for each system channel
- optional data drive
- optional UPS backup power supply
Downloads and links
Need some advice?